CITEL
Company History
Locations
Specialist in overvoltage protection
Service quality
citel and the environment
Test Facilities
New Range
Lightning Surges
Lightning and Transient overvoltages
The origin of overvoltages
Effects of lightning
Surge protectors
The "Surge protection" solution
International standards
New PV range: DPVN
Citel's VG Technology
CTC Technology
SPD mandatory or not
New range of SPDs
NEW: SPD+Counter
Products
AC/DC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
Miscellaneous
Applications
Toggle Dropdown
Datacenter
Energy Storage Systems
WATER TREATMENT
LED
Radiocommunication
Security Systems
Industrial Installation
Wind Turbine Installation
Domestic Photovoltaic
Industry Photovoltaic
Solar Farms
E-Moblility
Services
Exhibition information
Downloading
Video Files
Training
CITEL Statement
News
Contact
Product ranges
AC Power
Photovoltaic
LED
Telecom
Dataline
Radiocommunication
image/svg+xml
Wind Turbine
Accessories
AC Power
Type 1+2+3 AC surge protector
DAC1-13VGS-40-150
Type 1+2+3 AC surge protector - 3-phase+N
DAC1-13VGS-40-150
Part Number
821730124
Type 1 + 2 + 3 AC surge protector
VG Technology
In : 20 kA
Iimp : 12,5 kA on 10/350µs impulse
No leakage current
Pluggable module for each phase
Remote signaling
Optimized to TOV
EN 61643-11, IEC 61643-11 and UL1449 ed.5 compliance
Certified EN 61643-11 and IEC 61643-11
Datasheet
Installation Sheet
Tender specifications
Contact Us
The DAC1-13VG is an extreme duty Type 1+2+3 AC surge protector device designed to protect at the entrance of the electrical installation. This SPD is particularly useful in a high lightning density area where the risk of heavy surge current or even direct strike is high (eg: buildings equipped with lightning rods). The DAC1-13VG is one-pole SPD and can be used in common mode or common and differential mode. DAC1-13VG AC surge protectors are designed to be connected in multi-pole configuration to protect single-phase, 3-phase and 3-phase+Neutral AC networks, sometimes associated with a dedicated N/PE SPD.
Select another reference:
DAC1-13VGS-10-150
DAC1-13VGS-10-275
DAC1-13VGS-10-320
DAC1-13VGS-11-150
DAC1-13VGS-11-275
DAC1-13VGS-11-320
DAC1-13VGS-11-385
DAC1-13VGS-20-150
DAC1-13VGS-20-275
DAC1-13VGS-20-320
DAC1-13VGS-20-385
DAC1-13VGS-30-150
DAC1-13VGS-30-275
DAC1-13VGS-30-320
DAC1-13VGS-31-150
DAC1-13VGS-31-275
DAC1-13VGS-31-320
DAC1-13VGS-31-385
DAC1-13VGS-40-150
DAC1-13VGS-40-275
DAC1-13VGS-40-320
DAC1-13VGS-40-385
Electrical Properties
Mechanical Properties
Norms
Deconnector
Schemas
SPD type
1+2+3
Network
120/208 V 3-phase+N
AC system
TNS
Max. AC operating voltage
Uc
150 Vac
Temporary Over Voltage (TOV) Characteristics - 5 sec.
Without disconnection
UT
180 Vac withstand
Temporary Over Voltage (TOV) Characteristics - 120 mn
Without disconnection or with safety disconnection
UT
230 Vac withstand
Residual Current
Leakage current to Ground
Ipe
None
Follow current
If
None
Nominal discharge current
15 x 8/20 µs impulses
In
20 kA
Max. discharge current
max. withstand @ 8/20 µs by pole
Imax
50 kA
Total Maximum discharge current
max. total withstand @ 8/20 µs
Imax Total
200 kA
Impulse current by pole
max. withstand 10/350µs by pole
Iimp
12.5 kA
Total lightning current
max. total withstand @ 10/350µs
Itotal
50 kA
Withstand on Combination waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Uoc
6 kV
Specific energy by pole
max. withstand 10/350 µs
W/R
40 kJ/ohm
Protection mode(s)
L/PE and N/PE
Protection level L/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
L/PE
1.5 kV
Protection level N/PE
@ In (8/20µs) and @ 6 kV (1,2/50 µs)
Up N/PE
1.5 kV
Protection level N/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.4 kV
Residual voltage L/PE at 5 kA
@ 5 kA (8/20µs)
Up-5kA
0.4 kV
Admissible short-circuit current
Isccr
50 000 A
Network type
AC
Technology
VG Technology (MOV+GSG)
SPD configuration
3-phase+Neutral
Connection to Network
By screw terminals: 2.5-25mm² (35mm² rigid)
Format
Plug-in modular box
Plugable
Yes
Mounting
Symmetrical rail 35 mm (EN 60715)
Housing material
Thermoplastic UL94 V-0
Operating temperature
Tu
-40/+85°C
Protection rating
IP20
Failsafe mode
Disconnection from AC network
Disconnection indicator
1 mechanical indicator by pole - Red/Green
Spare module(s)
MDAC1-13VG-150
Remote signaling of disconnection
output on changeover contact
Wiring for remote signaling
1.5 mm² max.
Max. Voltage/Current for remote signaling
250 V / 0.5 A (AC) / 30 V / 3 A (DC)
Dimensions
See diagram - 4TE (EN43880)
Weight
0.528 kg
Standards compliance
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification
KEMA
Thermal disconnector
Internal
Installation ground fault breaker
Type 'S' or delayed
Back-up protection device
Fuse assembly: SFD1-13S-40 /or 125 A min. - 315 A max. - Fuses Type gG
×
Description:
Type 1+2+3 AC surge protector - 3-phase+N
Standards compliance:
IEC 61643-11 / EN 61643-11 / UL1449 ed.5
Certification:
KEMA / EAC
Technology:
VG Technology (MOV+GSG)
SPD configuration:
3-phase+Neutral
Remote signaling of disconnection:
output on changeover contact
SPD type :
1+2+3
Network:
120/208 V 3-phase+N
AC system:
TNS
Max. AC operating voltage :
150 Vac
Residual Current :
None
Max. discharge current :
50 kA
Total Maximum discharge current :
200 kA
Impulse current by pole :
12.5 kA
Admissible short-circuit current:
50 000 A
CITEL
Reference:
DAC1-13VGS-40-150
Part Number:
821730124
Or equivalent
Surge protection...in video !
Read more
Video|New range of SPDs
Read more